™ Xenon™ 1900/1902Area-Imaging ScannerUser’s Guide

Pagina 2 - Disclaimer

If you need more information on the collection, reuse, and recycling sys-tems, contact your local or regional waste administration.You may also contac

Pagina 3 - UL Statement

4 - 2Trigger ClickTo hear an audible click every time the scanner trigger is pressed, scan the Trigger Click On bar code below. Scan the Trigger Clic

Pagina 4 - Information

4 - 3Beeper Volume – Good ReadThe beeper volume codes modify the volume of the beep the scanner emits on a good read. Default = High.Beeper Pitch – G

Pagina 5

4 - 4Beeper Pitch – ErrorThe beeper pitch codes modify the pitch (frequency) of the sound the scan-ner emits when there is a bad read or error. Defau

Pagina 6 - South Korea

4 - 5Number of Beeps – Good ReadThe number of beeps of a good read can be programmed from 1 - 9. The same number of beeps will be applied to the beep

Pagina 7 - Solids and Water Protection

4 - 6Good Read DelayThis sets the minimum amount of time before the scanner can read another bar code. Default = 0 ms (No Delay).User-Specified Good

Pagina 8

4 - 7slightly less range than Normal mode. Enhanced mode is best used when you require a very fast scan speed and don’t require a long working range.

Pagina 9

4 - 8code, set the time-out duration (from 0-300,000 milliseconds) by scanning digits on the Programming Chart inside the back cover, then scanning Sa

Pagina 10 - Australia/NZ

4 - 9LED Illumination - Presentation ModeIf you wish to set the illumination LED brightness, scan one of the bar codes below. This sets the LED illum

Pagina 11

4 - 10Presentation SensitivityPresentation Sensitivity is a numeric range that increases or decreases the scanner's reaction time to bar code pre

Pagina 12 - International

4 - 11In the example below, the white box is the centering window. The centering window has been set to 20% left, 30% right, 8% top, and 25% bottom.

Pagina 13 - Required Safety Labels

JapanComplies with Technical Regulations Conformity Certification of Specified Radio equipment.KoreaThis product meets Korean agency approval.Mexico

Pagina 14 - CCB01-010BT Base

4 - 12Scan Presentation Centering On, then scan one of the following bar codes to change the top, bottom, left, or right of the centering window. The

Pagina 15 - Table of Contents

4 - 13You may program a Streaming Presentation Mode (Normal, Enhanced, or Mobile Phone) you wish to use for in-stand scanning, and a Manual Trigger mo

Pagina 16

4 - 14You cannot take images when in Streaming Presentation Mode. To take images, scan Image Snap and Ship (see page 4-15).Note: If you are using a c

Pagina 17

4 - 15Image Snap and ShipImage Snap and Ship tells the scanner to take a picture (rather than read a bar code) when the trigger is pressed. Once the

Pagina 18

4 - 16Use shorter delays in applications where repetitive bar code scanning is required. Reread Delay only works when in Presentation Mode (see page

Pagina 19

4 - 17Aimer DelayThe aimer delay allows a delay time for the operator to aim the scanner before the picture is taken. Use these codes to set the time

Pagina 20 - Chapter 6 - Data Formatting

4 - 18Aimer ModeThis feature allows you to turn the aimer on and off. When the Interlaced bar code is scanned, the aimer is interlaced with the illum

Pagina 21 - Chapter 7 - Symbologies

4 - 19In the example below, the white box is the centering window. The centering win-dow has been set to 20% left, 30% right, 8% top, and 25% bottom.

Pagina 22 - Chapter 8 - Imaging Commands

4 - 20Scan Centering On, then scan one of the following bar codes to change the top, bottom, left, or right of the centering window. Then scan the pe

Pagina 23 - Chapter 10 - Utilities

4 - 21Scan a bar code below to enable or disable Preferred Symbology. Default = Preferred Symbology Off.High Priority SymbologyTo specify the high

Pagina 24 - Appendix A - Reference Charts

InternationalLED Safety StatementScanner LEDs have been tested and classified as “EXEMPT RISK GROUP” to the standard: IEC 62471:2006.Radio TechnologyC

Pagina 25 - Getting Started

4 - 22bar code has been encountered. Scan the bar code below, then set the delay (from 1-3,000 milliseconds) by scanning digits from the inside back

Pagina 26 - Connecting the Device

4 - 23To Add an Output Sequence1. Scan the Enter Sequence symbol (see Require Output Sequence, page 4-26).2. Code I.D.On the Symbology Chart on page A

Pagina 27

4 - 24Output Sequence ExampleIn this example, you are scanning Code 93, Code 128, and Code 39 bar codes, but you want the scanner to output Code 39 1s

Pagina 28

4 - 25SEQBLKsequence editor start command62 code identifier for Code 390012 A - Code 39 sample length (11) plus CR suffix (1) = 1241 start character m

Pagina 29

4 - 26Require Output SequenceWhen an output sequence is Required, all output data must conform to an edited sequence or the scanner will not transmit

Pagina 30 - Connecting with RS485

4 - 27No ReadWith No Read turned On, the scanner notifies you if a code cannot be read. If using an EZConfig-Scanning Tool Scan Data Window (see page

Pagina 31

4 - 28Working OrientationSome bar codes are direction-sensitive. For example, KIX codes and OCR can misread when scanned sideways or upside down. Us

Pagina 32 - Reading Techniques

5 - 15Data EditingPrefix/Suffix OverviewWhen a bar code is scanned, additional information is sent to the host computer along with the bar code data.

Pagina 33 - Setting Custom Defaults

5 - 2symbology to which you want to apply the prefix or suffix. For example, for Code 128, Code ID is “j” and Hex ID is “6A”.Step 3. Scan the 2 hex d

Pagina 34

5 - 3Step 1. Scan the Clear One Prefix or Clear One Suffix symbol.Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in the Sy

Pagina 35 - Programming the Interface

Required Safety LabelsScannerCompliance Label locationPart Number, Serial Number and Revision InformationlocationIllumination output

Pagina 36 - RS232 Serial Port

5 - 4Suffix SelectionsFunction Code TransmitWhen this selection is enabled and function codes are contained within the scanned data, the scanner trans

Pagina 37 - RS485 Packet Length

5 - 5Intercharacter DelayAn intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be placed between the transmission of each charact

Pagina 38 - USB PC or Macintosh Keyboard

5 - 6Interfunction DelayAn interfunction delay of up to 5000 milliseconds (in 5ms increments) may be placed between the transmission of each segment

Pagina 39 - USB Serial

6 - 16Data FormattingData Format Editor IntroductionYou may use the Data Format Editor to change the scanner’s output. For exam-ple, you can use the

Pagina 40 - Gilbarco Settings

6 - 2you are programming. (See Primary/Alternate Data Formats on page 6-11 for further information.)Step 3. Terminal TypeRefer to Terminal ID Table (

Pagina 41 - NCR Bioptic Settings

6 - 3Other Programming SelectionsClear One Data Format This deletes one data format for one symbology. If you are clearing the primary format, scan

Pagina 42 - Terminal Default Settings

6 - 4Data Format Editor CommandsSend CommandsSend all charactersF1 Include in the output message all of the characters from the input message, startin

Pagina 43 - Keyboard Country Layout

6 - 5ASCII code, and xx stands for the insert character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252), beginni

Pagina 44 - Keyboard Country (continued)

6 - 6For example, B501021F inserts an “A” on a 104 key, U.S. style keyboard. B5 = the command, 01 = number of keys pressed (without the key modifier)

Pagina 45

6 - 7Search backward for a characterF9 Search the input message backward for “xx” character from the current cursor position, leaving the cursor point

Pagina 46

CCB01-010BT BasePart Number,SerialNumber and Revision Information locationCompliance Label locations

Pagina 47

6 - 8Miscellaneous CommandsSuppress charactersFB Suppress all occurrences of up to 15 different characters, starting at the current cursor position, a

Pagina 48

6 - 9Check for non-numeric characterED Check to make sure there is a non-numeric ASCII character at the current cursor position. The format is aborte

Pagina 49 - Keyboard Style

6 - 10Data Format Required, Keep Prefix/SuffixScanned data is modified according to your data format, and prefixes and suffixes are transmitted. Any

Pagina 50 - Autocaps via NumLock

6 - 11will sound. If you wish to hear the error tone when a non-matching bar code is found, scan the Data Format Non-Match Error Tone On bar code. D

Pagina 51 - Control Character Output

6 - 12For example, you may have set your device to the data format you saved as Data Format 3. You can switch to Data Format 1 for a single trigger p

Pagina 52 - Keyboard Modifiers

7 - 17SymbologiesThis programming section contains the following menu selections. Refer to Chapter 11 for settings and defaults.• All Symbologies • I

Pagina 53 - Default = Off

7 - 2All SymbologiesIf you want to decode all the symbologies allowable for your scanner, scan the All Symbologies On code. If on the other hand, you

Pagina 54 - RS232 Baud Rate

7 - 3Codabar<Default All Codabar Settings>Codabar On/OffCodabar Start/Stop CharactersStart/Stop characters identify the leading and trailing end

Pagina 55 - Default = None

7 - 4When Check Character is set to Validate, but Don’t Transmit, the unit will only read Codabar bar codes printed with a check character, but will n

Pagina 56 - RS232 Handshaking

7 - 5Codabar Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional infor

Pagina 57 - XON/XOFF On

iChapter 1 - Getting StartedAbout This Manual ... 1-1Unpacking Your Device...

Pagina 58 - Scanner-Bioptic Packet Mode

7 - 6Code 39< Default All Code 39 Settings >Code 39 On/OffCode 39 Start/Stop CharactersStart/Stop characters identify the leading and trailing e

Pagina 59 - Scanner-Bioptic ACK/NAK Mode

7 - 7When Check Character is set to Validate and Transmit, the scanner only reads Code 39 bar codes printed with a check character, and will transmit

Pagina 60

7 - 8acter(s), it buffers Code 39 bar codes until it reads a Code 39 bar code that does not have the append trigger. The data is then transmitted in

Pagina 61 - Cordless System Operation

7 - 9Full ASCIIIf Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character

Pagina 62

7 - 10and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual. The data characters should the

Pagina 63 - System Conditions

7 - 11When Check Digit is set to Validate and Transmit, the scanner only reads Interleaved 2 of 5 bar codes printed with a check digit, and will trans

Pagina 64 - About the Battery

7 - 12NEC 2 of 5< Default All NEC 2 of 5 Settings >NEC 2 of 5 On/OffCheck DigitNo Check Digit indicates that the scanner reads and transmits bar

Pagina 65 - Battery Recommendations

7 - 13NEC 2 of 5 Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional i

Pagina 66

7 - 14Code 93< Default All Code 93 Settings >Code 93 On/OffCode 93 Message LengthScan the bar codes below to change the message length. Refer t

Pagina 67

7 - 15which the bar codes are read, deleting the first space from each. The scanner transmits the appended data when it reads a Code 93 bar code that

Pagina 68 - Scanning While in Base Cradle

iiWincor Nixdorf Terminal Default Settings...2-8Wincor Nixdorf Beetle™ Terminal Default Settings...2-8Keyboard Country Layout...

Pagina 69 - Paging Mode

7 - 16Straight 2 of 5 Industrial (three-bar start/stop)<Default All Straight 2 of 5 Industrial Settings>Straight 2 of 5 Industrial On/OffStraigh

Pagina 70 - Error Indicators

7 - 17Straight 2 of 5 IATA (two-bar start/stop)<Default All Straight 2 of 5 IATA Settings>Straight 2 of 5 IATA On/OffStraight 2 of 5 IATA Messag

Pagina 71 - Base Address

7 - 18Matrix 2 of 5<Default All Matrix 2 of 5 Settings>Matrix 2 of 5 On/OffMatrix 2 of 5 Message LengthScan the bar codes below to change the me

Pagina 72 - Scanner Modes

7 - 19Code 11<Default All Code 11 Settings>Code 11 On/OffCheck Digits RequiredThis option sets whether 1 or 2 check digits are required with Cod

Pagina 73 - Unlinking the Scanner

7 - 20Code 11 Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional info

Pagina 74 - Out-of-Range Alarm

7 - 21that supports concatenation of neighboring symbols, and 4) the standard layout for bar codes on a blood product label. Use the bar codes below

Pagina 75 - Scanner Power Time-Out Timer

7 - 22Code 128 Code PageCode pages define the mapping of character codes to characters. If the data received does not display with the proper charact

Pagina 76 - Default = 3600

7 - 23GS1-128<Default All GS1-128 Settings>GS1-128 On/OffGS1-128 Message LengthScan the bar codes below to change the message length. Refer to

Pagina 77 - Flexible Power Management

7 - 24Telepen<Default All Telepen Settings>Telepen On/OffTelepen OutputUsing AIM Telepen Output, the scanner reads symbols with start/stop pat-t

Pagina 78 - :*:RESET_.³

7 - 25Telepen Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional info

Pagina 79 - Batch Mode Storage

iiiCharging Information... 3-5Battery Recommendations... 3-5Proper Disposal

Pagina 80 - Entering Quantities

7 - 26UPC-A Number SystemThe numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be

Pagina 81

7 - 27UPC-A Addenda SeparatorWhen this feature is on, there is a space between the data from the bar code and the data from the addenda. When turned

Pagina 82 - Quantity Codes

7 - 28Coupon GS1 DataBar OutputIf you scan coupons that have both UPC and GS1 DataBar codes, you may wish to scan and output only the data from the GS

Pagina 83 - Clear All Codes

7 - 29UPC-E0 ExpandUPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format. Default = Off.UPC-E0 Addenda RequiredWhen Required is scanned,

Pagina 84 - Multiple Scanner Operation

7 - 30UPC-E0 Check DigitCheck Digit specifies whether the check digit should be transmitted at the end of the scanned data or not. Default = On.UPC-E

Pagina 85

7 - 31UPC-E1Most U.P.C. bar codes lead with the 0 number system. For these codes, use UPC-E0 (page 7-28). If you need to read codes that lead with t

Pagina 86

7 - 32EAN/JAN-13 AddendaThis selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data. Default = Off for both 2 Digit and 5 Digit Adden

Pagina 87 - Application Work Groups

7 - 33EAN/JAN-13 Addenda SeparatorWhen this feature is On, there is a space between the data from the bar code and the data from the addenda. When tu

Pagina 88 - All Application Work Groups

7 - 34EAN/JAN-8<Default All EAN/JAN-8 Settings>EAN/JAN-8 On/OffEAN/JAN-8 Check DigitThis selection allows you to specify whether the check digit

Pagina 89

7 - 35EAN/JAN-8 AddendaThis selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data.Default = Off for both 2 Digit and 5 Digit Addenda.E

Pagina 90 - Bluetooth PIN Code

ivBatch Mode Transmit Delay ...3-24Multiple Scanner Operation ...3-24Scanner Name...

Pagina 91

7 - 36MSI<Default All MSI Settings>MSI On/OffMSI Check CharacterDifferent types of check characters are used with MSI bar codes. You can progra

Pagina 92 - PDAs/Mobility Systems Devices

7 - 37When Check Character is set to Validate Type 10/11, but Don’t Transmit, the unit will only read MSI bar codes printed with the specified type ch

Pagina 93 - Auto Reconnect Mode

7 - 38GS1 DataBar Omnidirectional< Default All GS1 DataBar Omnidirectional Settings >GS1 DataBar Omnidirectional On/OffGS1 DataBar Limited< D

Pagina 94 - Maximum Link Attempts

7 - 39GS1 DataBar Expanded< Default All GS1 DataBar Expanded Settings >GS1 DataBar Expanded On/OffGS1 DataBar Expanded Message LengthScan the ba

Pagina 95 - Relink Time-Out

7 - 40Trioptic CodeNote: If you are going to scan Code 32 Pharmaceutical codes (page 7-8), Trioptic Code must be off.Trioptic Code is used for labelin

Pagina 96 - Host Command Acknowledgment

7 - 41Codablock A Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional

Pagina 97

7 - 42Codablock F<Default All Codablock F Settings>Codablock F On/OffCodablock F Message LengthScan the bar codes below to change the message le

Pagina 98 - * Host ACK Off

7 - 43PDF417< Default All PDF417 Settings >PDF417 On/OffPDF417 Message LengthScan the bar codes below to change the message length. Refer to Me

Pagina 99 - Input/Output Settings

7 - 44MacroPDF417MacroPDF417 is an implementation of PDF417 capable of encoding very large amounts of data into multiple PDF417 bar codes. When this

Pagina 100 - Trigger Click

7 - 45MicroPDF417 Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional

Pagina 101 - Beeper Pitch – Good Read

vUser-Specified Good Read Delay ... 4-6Manual Trigger Modes ... 4-6LED Illumination

Pagina 102 - LED – Good Read

7 - 46GS1 Composite Code Message LengthScan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for addi

Pagina 103 - Default = 1

7 - 47Default = GS1 Emulation Off.TCIF Linked Code 39 (TLC39)This code is a composite code since it has a Code 39 linear component and a MicroPDF417 s

Pagina 104 - Manual Trigger Modes

7 - 48QR Code< Default All QR Code Settings >QR Code On/OffThis selection applies to both QR Code and Micro QR Code.QR Code Message LengthScan t

Pagina 105 - Serial Trigger Mode

7 - 49information encoded in those bar codes. Once the proper number of codes is reached, the data is output in the order specified in the bar codes.

Pagina 106 - Presentation Mode

7 - 50Data Matrix< Default All Data Matrix Settings >Data Matrix On/OffData Matrix Message LengthScan the bar codes below to change the message

Pagina 107 - LEDs Off

7 - 51mined by information encoded in those bar codes. Once the proper num-ber of codes is reached, the data is output in the order specified in the

Pagina 108 - Sensitivity

7 - 52MaxiCode< Default All MaxiCode Settings >MaxiCode On/OffMaxiCode Message LengthScan the bar codes below to change the message length. Re

Pagina 109 - Bar Code 2

7 - 53Aztec Code< Default All Aztec Code Settings >Aztec Code On/OffAztec Code Message LengthScan the bar codes below to change the message leng

Pagina 110 - In-Stand Sensor Mode

7 - 54ter(s), it buffers the number of Aztec bar codes determined by information encoded in those bar codes. Once the proper number of codes is reach

Pagina 111 - Streaming Presentation

7 - 55Chinese Sensible (Han Xin) Code< Default All Han Xin Settings >Han Xin Code On/OffHan Xin Code Message LengthScan the bar codes below to c

Pagina 112 - Mobile Phone Read Mode

DisclaimerHoneywell International Inc. (“HII”) reserves the right to make changes in speci-fications and other information contained in this document

Pagina 113 - Reread Delay

viRequire Output Sequence ...4-26Multiple Symbols...4-26No Read..

Pagina 114 - Illumination Lights

7 - 56Postal Codes - 2DThe following lists the possible 2D postal codes, and 2D postal code combina-tions that are allowed. Only one 2D postal code s

Pagina 115 - Scanner Time-Out

7 - 57Combination 2D Postal Codes:Postnet with B and B’ Fields OnInfoMail OnPostnet OnAlso see Postnet Check Digit, page 7-59.Planet Code and Postnet

Pagina 116 - Centering

7 - 58Planet Code, Postal-4i, and Intelligent Mail Bar Code OnPostnet, Postal-4i, and Intelligent Mail Bar Code OnPlanet Code, Postal-4i, and Postnet

Pagina 117

7 - 59Planet Code Check DigitThis selection allows you to specify whether the check digit should be transmitted at the end of Planet Code data. Defau

Pagina 118 - Preferred Symbology

7 - 60Postal Codes - LinearThe following lists linear postal codes. Any combination of linear postal code selections can be active at a time. China

Pagina 119 - Preferred Symbology Time-out

7 - 61China Post (Hong Kong 2 of 5) On/OffChina Post (Hong Kong 2 of 5) Message LengthScan the bar codes below to change the message length. Refer to

Pagina 120 - Output Sequence Overview

7 - 62Korea Post<Default All Korea Post Settings>Korea PostKorea Post Message LengthScan the bar codes below to change the message length. Refe

Pagina 121 - Discard

8 - 18Imaging CommandsThe scanner is like a digital camera in the way it captures, manipulates, and transfers images. The following commands allow yo

Pagina 122 - Output Sequence Example

8 - 2Step 1 - Take a Picture Using IMGSNPImage Snap - IMGSNPAn image is taken whenever the hardware button is pressed, or when the Image Snap (IMGSNP)

Pagina 123 - * Discard Partial Sequence

8 - 3E - ExposureExposure is used in Manual Style only (2P), and allows you to set the expo-sure time. This is similar to setting a shutter speed on

Pagina 124 - Multiple Symbols

viiChapter 7 - SymbologiesAll Symbologies... 7-2Message Length Description...

Pagina 125 - Video Reverse

8 - 4W - Target White ValueSets the target for the median grayscale value in the captured image. For capturing close-up images of high contrast docum

Pagina 126 - Working Orientation

8 - 5Step 2 - Ship a Picture Using IMGSHPImage Ship - IMGSHPAn image is taken whenever the button is pressed, or when the Image Snap (IMGSNP) command

Pagina 127 - Default

8 - 6C - CompensationFlattens the image to account for variations in illumination across the image.0C Compensation disabled (default)1C Compensation e

Pagina 128

8 - 7E - Edge SharpenAn edge sharpen filter cleans up the edges of an image, making it look cleaner and sharper. While edge sharpening does make the

Pagina 129 - Clear All Prefixes

8 - 8H - Histogram StretchIncreases the contrast of the transmitted image. Not available with some image formats. 0H No stretch (default)1H Histogr

Pagina 130 - Intermessage Delays

8 - 9IF- Noise ReductionUsed to reduce the salt and pepper noise in an image.0if No salt and pepper noise reduction (default)1if Salt and pepper noise

Pagina 131 - Intercharacter Delay

8 - 10J - JPEG Image QualitySets the desired quality when the JPEG image format is selected. Higher numbers result in higher quality, but larger file

Pagina 132 - Intermessage Delay

8 - 11nB The bottom edge of the shipped image corresponds to row n - 1 of the image in memory. Range: 000 - 639. (Default = all rows)Alternately, s

Pagina 133 - * Default Data Format

8 - 121S ship every pixel (default)2S ship every 2nd pixel, both horizontally and vertically3S ship every 3rd pixel, both horizontally and vertically

Pagina 134 - Enter Data Format

8 - 13V - Blur ImageSmooths transitions by averaging the pixels next to the hard edges of defined lines and shaded areas in an image. 0V Don’t blur

Pagina 135 - Clear All Data Formats

viiiCodablock A ...7-40Codablock F...

Pagina 136 - Terminal ID Table

8 - 14Image Size CompatibilityIf you have applications that expect an image ship to return exactly 640x480 pixels, scan the Force VGA Resolution bar c

Pagina 137 - Insert key strokes

8 - 15The following IMGBOX example was executed and viewed using QuickView software. This software is available at www.honeywellaidc.com. Click on S

Pagina 138 - Search Commands

8 - 16This option is used to size the image horizontally. If using this option, set the resolution (R) to zero.B - Output Image Height This option

Pagina 139 - Search backward for a string

8 - 178F BMP formatH - Height of Signature Capture AreaThe height of the signature capture area must be measured in inches divided by .01. In the exa

Pagina 140 - Miscellaneous Commands

8 - 18For example, use 2500 to specify a resolution of 2.5. Set to zero when using the A and B modifiers (see A - Output Image Width and B - Output

Pagina 141 - Data Formatter

8 - 19Y - Vertical Bar Code OffsetThe vertical bar code offset allows you to offset the vertical center of the signature capture area. Negative numbe

Pagina 143

9 - 19Interface KeysKeyboard Function RelationshipsThe following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply

Pagina 144 - Data Format

9 - 2The last five characters in the Full ASCII “CTRL”+ column ( [ \ ] 6 - ), apply to US only. The following chart indicates the equivalents of the

Pagina 145 - Symbologies

9 - 3Supported Interface KeysASCII HEXIBM PC/AT and Compatibles, USB PC KeyboardApple Mac/iMac Supported KeysNUL 00 Reserved ReservedSOH 01 Enter (KP

Pagina 146 - All Symbologies Off

ixChapter 9 - Interface KeysKeyboard Function Relationships ... 9-1Supported Interface Keys...

Pagina 148 - D5 6 7 8A

10 - 110UtilitiesTo Add a Test Code I.D. Prefix to All SymbologiesThis selection allows you to turn on transmission of a Code I.D. before the decoded

Pagina 149 - Maximum Message Length

10 - 2Show Data FormatScan the bar code below to show current data format settings.Test MenuWhen you scan the Test Menu On code, then scan a programmi

Pagina 150 - Code 39 Check Character

10 - 3Application Plug-Ins (Apps)Any apps that you are using can be turned off or on by scanning the following bar codes. Apps are stored in groups:

Pagina 151 - Code 39 Append

10 - 4Scan DataScan Data allows you to scan bar codes and display the bar code data in a window. Scan Data lets you send serial commands to the scann

Pagina 152 - Default = Off

10 - 59. If you’ve selected the defaults during installation, you can click on Start Menu-All Programs-Honeywell-EZConfig-Scanning.

Pagina 154 - Code 39 Code Page

11 - 111Serial Programming CommandsThe serial programming commands can be used in place of the programming bar codes. Both the serial commands and th

Pagina 155 - Default = No Check Digit

11 - 2Storage A single character that specifies the storage table to which the command is applied. An exclamation point (!) performs the command’s op

Pagina 156 - NEC 2 of 5

11 - 3ResponsesThe device responds to serial commands with one of three responses:ACK Indicates a good command which has been processed.ENQ Indicates

Pagina 157

xKeyboard Wedge ...12-8Serial Output ...12-9RS485 Ou

Pagina 158

11 - 4MAX60[ACK],DFT[ACK].This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on; the Start/Stop Character (SSX)

Pagina 159 - Code 93 Code Page

11 - 5Menu CommandsSelectionSetting* Indicates defaultSerial Command# Indicates a numeric entryPageProduct Default SettingsSetting Custom DefaultsSet

Pagina 160

11 - 6Plug and Play Codes:RS485IBM Port 5B InterfacePAPP 5B 2-2IBM Port 9B HHBCR-1 InterfacePAP9B1 2-2IBM Port 17 InterfacePAPP 17 2-2IBM Port 9B HHBC

Pagina 161

11 - 7Plug and Play Codes Verifone Ruby Ter min alPAPRBY 2-6Gilbarco Terminal PAPGLB 2-6Honeywell Bioptic Aux PortPAPBIO 2-7Datalogic Magellan Bioptic

Pagina 162

11 - 8Program Keyboard CountryCzech (Programmers)KBDCTY40 2-10Czech (QWERTY) KBDCTY39 2-10Czech (QWERTZ) KBDCTY38 2-10Denmark KBDCTY8 2-10Dutch (Nethe

Pagina 163 - Check Digits Required

11 - 9Program Keyboard CountryLatvia (QWERTY) KBDCTY43 2-13Lithuania KBDCTY44 2-13Lithuania (IBM) KBDCTY45 2-13Macedonia KBDCTY34 2-13Malta KBDCTY74 2

Pagina 164

11 - 10Program Keyboard CountryUkrainian KBDCTY76 2-15United Kingdom KBDCTY7 2-15United Stated (Dvorak right)KBDCTY89 2-15United States (Dvorak left)K

Pagina 165 - Code 128 Append

11 - 11Keyboard Modifiers *Control + ASCII Off KBDCAS0 2-18DOS Mode Control + ASCIIKBDCAS1 2-18Windows Mode Control + ASCIIKBDCAS2 2-18Windows Mode Pr

Pagina 166 - Code 128 Code Page

11 - 12Word Length: Data Bits, Stop Bits, and Parity7 Data, 1 Stop, Parity Even232WRD32-217 Data, 1 Stop, Parity None232WRD0 2-217 Data, 1 Stop, Pari

Pagina 167

11 - 13Scanner-Bioptic ACK/NAK Mode*Bioptic ACK/NAK Off232NAK0 2-25Bioptic ACK/NAK On232NAK1 2-25Scanner-Bioptic ACK/NAK TimeoutACK/NAK Timeout*510023

Pagina 168 - Telepen Output

1 - 11Getting StartedAbout This ManualThis User’s Guide provides installation and programming instructions for the Xenon™ 1900 and 1902 area-imaging s

Pagina 169 - UPC-A Check Digit

11 - 14Scanner Modes Charge Only Mode :*:BASLNK0 3-12*Charge and Link Mode:*:BASLNK1 3-12Locked Link Mode BASCON0,DNG1 3-13*Open Link Mode BASCON1,DNG

Pagina 170 - UPC-A Addenda Required

11 - 15Batch Mode Automatic Batch ModeBATENA1 3-19*Batch Mode Off BATENA0 3-19Inventory Batch ModeBATENA2 3-19Batch Mode Beep Off BATBEP0 3-19*On BATB

Pagina 171 - UPC-A/EAN-13

11 - 16Multiple ScannerOperationMultiple Scanner OperationBASCON2,DNG3 3-25Scanner Name Name 1-7 BT_NAM##### 3-26Reset RESET_ 3-26Scanner Name BT_NAM

Pagina 172 - Coupon GS1 DataBar Output

11 - 17Input/Output SelectionsPower Up Beeper Power Up Beeper Off - ScannerBEPPWR0 4-1*Power Up Beeper On - ScannerBEPPWR1 4-1Power Up Beeper Off - Co

Pagina 173 - UPC-E0 Addenda Separator

11 - 18Number of Beeps - Error *1 BEPERR3 4-5Range 1 - 9 BEPERR# 4-5Number of Beeps - Good Read *1 BEPRPT1 4-5Range 1 - 9 BEPRPT# 4-5Good Read Delay *

Pagina 174 - UPC-E0 Addenda

11 - 19Presentation Centering WindowPresentation Centering OnPDCWIN1 4-12*Presentation Centering OffPDCWIN0 4-12Left of Presentation Centering Window

Pagina 175 - EAN/JAN-13

11 - 20Image Snap and ShipImage Snap and ShipTRGMOD6 4-15Hands Free Time-OutRange 0 - 300,000 msTRGPTO###### 4-15Reread Delay Short (500 ms) DLYRRD500

Pagina 176 - EAN/JAN-13 Addenda Required

11 - 21Preferred Symbology On PRFENA1 4-21*Off PRFENA0 4-21High Priority SymbologyPRFCOD## 4-21Low Priority SymbologyPRFBLK## 4-21Preferred Symbology

Pagina 177 - ISBN Translate

11 - 22Working Orientation *Upright ROTATN0 4-28Vertical, Bottom to Top (Rotate CCW 90°)ROTATN1 4-28Upside Down ROTATN2 4-28Vertical, Top to Bottom (R

Pagina 178 - EAN/JAN-8

11 - 23Data Formatter SelectionsData Format Editor *Default Data Format (None)DFMDF3 6-1Enter Data Format DFMBK3## 6-2Clear One Data FormatDFMCL3 6-3C

Pagina 179 - EAN/JAN-8 Addenda Separator

1 - 2Connecting the DeviceConnecting with USBA scanner or a cordless base can be connected to the USB port of a com-puter. 1. Connect the appropriate

Pagina 180 - MSI Check Character

11 - 24Single Scan Data Format ChangeSingle Scan-Primary Data FormatVSAF_0 6-12Single Scan-Data Format 1VSAF_1 6-12Single Scan-Data Format 2VSAF_2 6-1

Pagina 181 - MSI Message Length

11 - 25Code 39 Start/Stop Char.*Don’t Transmit C39SSX0 7-6Transmit C39SSX1 7-6Code 39 Check Char. *No Check Char. C39CK20 7-7Validate, But Don’t Tra n

Pagina 182 - GS1 DataBar Limited

11 - 26NEC 2 of 5 Default All NEC2 of 5 SettingsN25DFT 7-12Off N25ENA0 7-12*On N25ENA1 7-12NEC 2 of 5 Check Digit*No Check Char. N25CK20 7-12Validate,

Pagina 183

11 - 27Straight 2 of 5 IATA *Off A25ENA0 7-17On A25ENA1 7-17Straight 2 of 5 IATA Message LengthMinimum (1 - 48) *4 A25MIN## 7-17Maximum (1 - 48) *

Pagina 184 - Codablock A

11 - 28Code 128 Code Page Code 128 Code Page (*2)128DCP## 7-22GS1-128 Default All GS1-128 SettingsGS1DFT 7-23*On GS1ENA1 7-23Off GS1ENA0 7-23GS1-128 M

Pagina 185

11 - 29UPC-A Addenda SeparatorOff UPAADS0 7-27*On UPAADS1 7-27UPC-A/EAN-13 with Extended Coupon Code*Off CPNENA0 7-27Allow Concatenation CPNENA1 7-27R

Pagina 186

11 - 30EAN/JAN-13 Check DigitOff E13CKX0 7-31*On E13CKX1 7-31EAN/JAN-13 2 Digit Addenda2 Digit Addenda On E13AD21 7-32*2 Digit Addenda Off E13AD20 7-3

Pagina 187 - Minimum Message Length

11 - 31MSI Check Character *Validate Type 10, but Don’t TransmitMSICHK0 7-37Validate Type 10 and Tra nsm itMSICHK1 7-37Validate 2 Type 10 Chars, but D

Pagina 188 - MicroPDF417

11 - 32GS1 DataBar ExpandedDefault All GS1 DataBar Expanded SettingsRSEDFT 7-39Off RSEENA0 7-39*On RSEENA1 7-39GS1 DataBar Expanded Msg. LengthMinimum

Pagina 189 - GS1 Composite Codes

11 - 33PDF417 Msg. Length Minimum (1-2750) *1PDFMIN 7-43Maximum (1-2750) *2750PDFMAX 7-43MacroPDF417 *On PDFMAC1 7-44Off PDFMAC0 7-44MicroPDF417 Defa

Pagina 190

1 - 32. Make sure the cables are secured in the wireways in the bottom of the cordless base and that the base sits flat on a horizontal surface.3. The

Pagina 191 - TCIF Linked Code 39 (TLC39)

11 - 34QR Code Default All QR Code SettingsQRCDFT 7-55*On QRCENA1 7-48Off QRCENA0 7-48QR Code Msg. LengthMinimum (1-7089) *1QRCMIN 7-48Maximum (1-7089

Pagina 192

11 - 35Aztec Code Msg. LengthMinimum (1-3832) *1AZTMIN 7-53Maximum (1-3832) *3832AZTMAX 7-53Aztec Append On AZTAPP1 7-54*Off AZTAPP0 7-54Aztec Code Pa

Pagina 193 - QR Code Page

11 - 36Combination 2D Postal CodesInfoMail and British Post OnPOSTAL8 7-57Intelligent Mail Bar Code and Postnet with B and B’ Fields OnPOSTAL20 7-57P

Pagina 194

11 - 37Combination 2D Postal Codes(continued)Postnet, Postal-4i, and Intelligent Mail Bar Code OnPOSTAL24 7-58Planet, Postal-4i, and Postnet with B an

Pagina 195 - Data Matrix Code Page

11 - 38China Post (Hong Kong 2 of 5) Default All China Post (Hong Kong 2 of 5) SettingsCPCDFT 7-60*Off CPCENA0 7-61On CPCENA1 7-61China Post (Hong Kon

Pagina 196

11 - 39Imaging Default CommandsImage Snap Default all Imaging CommandsIMGDFT 8-1Imaging Style - DecodingSNPSTY0 8-2*Imaging Style - PhotoSNPSTY1 8-2Im

Pagina 197

11 - 40Image Ship *Infinity Filter - Off IMGINF0 8-5Infinity Filter - On IMGINF1 8-5*Compensation Off IMGCOR0 8-6Compensation On IMGCOR1 8-6*Pixel Dep

Pagina 198 - Aztec Code Page

11 - 41Image Ship (continued)Invert Image around X axisIMGNVX1 8-8Invert Image around Y axisIMGNVY1 8-8Rotate Image none IMGROT0 8-9Rotate Image 90° r

Pagina 199

11 - 42Image Ship (continued)Ship Every 2nd Pixel IMGSUB2 8-12Ship Every 3rd Pixel IMGSUB3 8-12*Document Image Filter OffIMGUSH0 8-12Document Image Fi

Pagina 200 - Postal Codes - 2D

12 - 112Product Specifications1900/1910 Scanner Product SpecificationsParameter SpecificationDimensions (Typical):Height6.3 inches (16cm)Length4.1 inc

Pagina 201 - Combination 2D Postal Codes:

1 - 43. Make sure the cables are secured in the wireways in the bottom of the cordless base and that the base sits flat on a horizontal surface.4. Tur

Pagina 202

12 - 21902/1912 Scanner Product SpecificationsHumidity 0 to 95% non-condensingMechanical DropOperational after 50 drops from 6 feet (1.83m) to concret

Pagina 203 - Postnet Check Digit

12 - 3*Storage outside of this temperature range could be detrimental to battery life.CCB01-010BT Charge Base Product SpecificationsRadio:Frequency2.4

Pagina 204 - Postal Codes - Linear

12 - 4Temperature Ranges:Operating32° F to +122° F (0° C to +50° C)Battery Charge41° F to +104° F (5° C to +40° C)Storage-40° F to +158° F (-40° C to

Pagina 205

12 - 5Depth of Field ChartsB&W Scanner Typical Performance FocusHigh Density (HD)Standard Range (SR)Extended Range (ER)SymbologyNear DistanceFar D

Pagina 206 - Korea Post

12 - 6B&W Scanner Guaranteed Performance FocusHigh Density (HD)Standard Range (SR)Extended Range (ER)SymbologyNear DistanceFar DistanceNear Distan

Pagina 207 - Imaging Commands

12 - 7Color Scanner (Model COL) Typical Performance FocusHigh Density (HD)Standard Range (SR)SymbologyNear DistanceFar DistanceNear DistanceFar Distan

Pagina 208 - (default)

12 - 8Color Scanner (Model COL) Guaranteed Performance CCB01-010BT Charge Base MountingFocusHigh Density (HD)Standard Range (SR)SymbologyNear Distance

Pagina 209 - (Default = 7874)

12 - 9Standard Cable PinoutsKeyboard Wedge10 Pin RJ41 Modular Plugconnects to the base1 Cable shield2Cable select3 Supply ground4 Terminal data5 Termi

Pagina 210

12 - 10Standard Cable PinoutsSerial Output 10 Pin RJ41 Modular Plugconnects to the base1 Cable shield2Cable select3 Supply ground4 Transmit data5 Rece

Pagina 211 - (default)

12 - 11Standard Cable PinoutsRS485 Output 10 Pin RJ41 Modular Plugconnects to the base1 Cable shield2Cable select3 Supply ground4 Transmit data5 Recei

Pagina 212

1 - 5Connecting with RS232 Serial Port1. Turn off power to the terminal/computer.2. Connect the appropriate interface cable to the scanner.Note: For t

Pagina 213

12 - 12Standard Cable PinoutsUSB10 Pin Modular Plugconnects to the base1 Cable shield2 Cable select3 Supply ground4567 +5V power89Data +10 Data -Note:

Pagina 214

13 - 113MaintenanceRepairsRepairs and/or upgrades are not to be performed on this product. These ser-vices are to be performed only by an authorized

Pagina 215

13 - 2Important! The following cleaning solutions have been tested to assure safe cleaning of your scanner’s disinfectant-ready housing. They are the

Pagina 216

13 - 3Replacing an Interface Cable1. Turn the power to the host system OFF.2. Disconnect the scanner’s cable from the terminal or computer.3. Locate t

Pagina 217

13 - 4Changing a scanner Battery1. Loosen the thumb wheel screw on the end cap by hand or use a hex wrench.2. Remove the battery from the handle.3. In

Pagina 218 - (default)

13 - 5• The scanner may not be programmed for the appropriate terminal interface. For example, you scan “12345” and the host displays “@es%.”Reprogram

Pagina 219

13 - 6Troubleshooting a Cordless ScannerNote: Make sure that your scanner’s battery is charged.Visit the Services and Support section of our website (

Pagina 220 - Signature Capture Optimize

14 - 114Customer SupportTechnical AssistanceIf you need assistance installing or troubleshooting your device, please call your distributor or the near

Pagina 221 - IMGBOX Modifiers

14 - 2Online Technical AssistanceYou can also access technical assistance online at www.honeywellaidc.com.Product Service and RepairHoneywell Internat

Pagina 222

14 - 3JapanTelephone: +81-3-6730-7344Fax: +81-3-6730-7222E-mail: [email protected] Product Service and Repair AssistanceYou can also ac

Pagina 223 - Example: IMGBOX245w37h55y

Product Agency Compliance - Xenon 1900USAFCC Part 15 Subpart B Class BThis device complies with part 15 of the FCC Rules. Operation is subject to the

Pagina 224

1 - 63. Make sure the cables are secured in the wireways in the bottom of the cordless base and that the base sits flat on a horizontal surface.4. Plu

Pagina 225 - RF Default Imaging Device

14 - 4HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH INJURIES, LOSSES, OR DAMAGES. SOME STATES, PROVINCES, OR COUNTRIES DO NOT ALLOW THE EXCLUSION OR L

Pagina 226

A - 1AReference ChartsSymbology ChartSymbology AIM IDPossible AIM ID Modifiers (m)Code ID (hex)All Symbologies (0x99)Australian Post ]X0 A (0x41)Azte

Pagina 227 - Interface Keys

A - 2EAN-8 with Add-On ]E3 D (0x44)GS1 Composite ]em0-3 y (0x79)GS1 DataBar ]em0y (0x79)GS1 DataBar Limited ]em{ (0x7B)GS1 DataBar Omnidirectiona

Pagina 228

A - 3Note: “m” represents the AIM modifier character. Refer to International Technical Specification, Symbology Identifiers, for AIM modifier charact

Pagina 229 - Supported Interface Keys

A - 4ASCII Conversion Chart (Code Page 1252)Note: This table applies to U.S. style keyboards. Certain characters may differ depending on your Country

Pagina 230

A - 540 28 ( 72 48 H 104 68 h41 29 ) 73 49 I 105 69 i42 2A * 74 4A J 106 6A j43 2B + 75 4B K 107 6B k44 2C , 76 4C L 108 6C l45 2D - 77 4D M 109 6D m

Pagina 231 - Utilities

A - 6Code Page Mapping of Printed Bar CodesCode pages define the mapping of character codes to characters. If the data received does not display with

Pagina 232 - Data Format Settings

A - 7one the host program is expecting. If this is the case, select the code page with which the bar codes were created. The data characters should

Pagina 233 - Application Plug-Ins (Apps)

A - 8Unicode Key Maps6E70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E4B 50 554C 51 560102 03 04 05 06 07 08 09 0A 0B 0C 0D 0F10 11 12 1314 15 16 17 18 1

Pagina 234 - Configure

Sample SymbolsUPC-A0 123456 7890Interleaved 2 of 5Code 128EAN-13Code 39Codabar1234567890Code 1289 780330 290951BC321A13579BCode 93123456-9$Straigh

Pagina 235

1 - 72. Make sure the cables are secured in the wireways in the bottom of the cordless base and that the base sits flat on a horizontal surface.3. Tur

Pagina 236

Sample Symbols6543210GS1 DataBar(01)00123456789012PDF417PostnetCar RegistrationZip CodeData MatrixQR CodeTes t SymbolNumbersMatrix 2 of 5ID-tag (UPU 4

Pagina 237 - Serial Programming Commands

Sample SymbolsAztecMaxiCodeMicro PDF417Package LabelTest MessageTest Message

Pagina 238 - Query Commands

Programming Chart1023675489

Pagina 239 - Examples of Query Commands

Programming ChartNote: If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correct letters or dig

Pagina 240 - Resetting the Custom Defaults

Honeywell Scanning & Mobility9680 Old Bailes RoadFort Mill, SC 29707Xenon-UG Rev D10/11

Pagina 241 - # Indicates a numeric

1 - 8Reading TechniquesThe Xenon 1900 and 1902 scanners have a view finder that projects a bright red aiming beam that corresponds to the scanner’s ho

Pagina 242

1 - 9The aiming beam or pattern is smaller when the scanner is closer to the code and larger when it is farther from the code. Symbologies with small

Pagina 243

1 - 10Resetting the Custom DefaultsIf you want the custom default settings restored to your scanner, scan the Acti-vate Custom Defaults bar code below

Pagina 244

2 - 12Programming the InterfaceIntroductionThis chapter describes how to program your system for the desired interface.Programming the Interface - Plu

Pagina 245

2 - 2RS232 Serial PortThe RS232 Interface bar code is used when connecting to the serial port of a PC or terminal. The following RS232 Interface bar

Pagina 246

2 - 3Each bar code above also programs the following suffixes for each symbology:* Suffixes programmed for Code 128 with IBM 4683 Port 5B, IBM 4683 Po

Pagina 247

2 - 4USB IBM SurePosScan one of the following “Plug and Play” codes to program the scanner for an IBM SurePos (USB handheld scanner) or IBM SurePos (U

Pagina 248

2 - 5USB HIDScan the following code to program the scanner for USB HID bar code scan-ners.USB SerialScan the following code to program the scanner to

Pagina 249

CanadaIndustry Canada ICES-003This Class B digital apparatus complies with Canadian ICES-003. Opera-tion is subject to the following conditions:1. Th

Pagina 250

2 - 6Verifone® Ruby Terminal Default SettingsScan the following Plug and Play code to program the scanner for a Verifone Ruby terminal. This bar code

Pagina 251

2 - 7Honeywell Bioptic Aux Port ConfigurationScan the following Plug and Play code to program the scanner for a Honeywell bioptic scanner auxiliary po

Pagina 252

2 - 8Wincor Nixdorf Terminal Default SettingsScan the following Plug and Play code to program the scanner for a Wincor Nix-dorf terminal. This bar co

Pagina 253

2 - 9Keyboard Country LayoutScan the appropriate country code below to program the keyboard layout for your country or language. As a general rule, th

Pagina 254

2 - 10Keyboard Country (continued)Bulgaria (Latin)Canada (French)Canada (Multilingual)CroatiaCzechCzech (Programmers)Czech (QWERTY)Czech (QWERTZ)Bulga

Pagina 255

2 - 11Keyboard Country (continued)FinlandGaelicGermanyGreekGreek (220 Latin)Greek (220)Greek (319 Latin)Greek (319)FaeroeseFranceEstoniaGreek (Latin)G

Pagina 256

2 - 12Keyboard Country (continued)Italian (142)Hungarian (101 key)IcelandIrishItalyJapan ASCIIKazakhKyrgyz (Cyrillic)HebrewHungaryGreek (Polytonic)Lat

Pagina 257

2 - 13Keyboard Country (continued)Lithuania (IBM)MaltaMongolian (Cyrillic)NorwayPolandPolish (214)Polish (Programmers)PortugalLithuaniaMacedoniaLatvia

Pagina 258

2 - 14Keyboard Country (continued)SCSSerbia (Latin)SlovakiaSlovakia (QWERTY)Slovakia (QWERTZ)SloveniaSpainSpanish variationRussian (Typewriter)Serbia

Pagina 259

2 - 15Keyboard Country (continued)Keyboard StyleThis programs keyboard styles, such as Caps Lock and Shift Lock. If you have used Keyboard Conversion

Pagina 260

This product has required the extraction and use of natural resources for its production. It may contain hazardous substances that could impact health

Pagina 261

2 - 16Regular is used when you normally have the Caps Lock key off.Caps Lock is used when you normally have the Caps Lock key on.Shift Lock is used wh

Pagina 262

2 - 17Emulate External Keyboard should be scanned if you do not have an external keyboard (IBM AT or equivalent). Note: After scanning the Emulate Ex

Pagina 263

2 - 18Default = Off.Keyboard ModifiersThis modifies special keyboard features, such as CTRL+ ASCII codes and Turbo Mode.Control + ASCII Mode On: The s

Pagina 264

2 - 19Turbo Mode: The scanner sends characters to a terminal faster. If the terminal drops characters, do not use Turbo Mode. Default = OffNumeric

Pagina 265

2 - 20RS232 Baud RateBaud Rate sends the data from the scanner to the terminal at the specified rate. The host terminal must be set for the same baud

Pagina 266

2 - 21RS232 Word Length: Data Bits, Stop Bits, and ParityData Bits sets the word length at 7 or 8 bits of data per character. If an applica-tion requ

Pagina 267

2 - 22RS232 Receiver Time-OutThe unit stays awake to receive data until the RS232 Receiver Time-Out expires. A manual or serial trigger resets the ti

Pagina 268

2 - 23RS232 TimeoutWhen using Flow Control with Timeout, you must program the length of the delay you want to wait for CTS from the host. Set the len

Pagina 269

2 - 24the scanner waits for ACK/NAK again. Turn on the ACK/NAK protocol by scanning the ACK/NAK On bar code below. To turn off the protocol, scan AC

Pagina 270

2 - 25Scanner-Bioptic ACK/NAK ModeBioptic ACK/Nak On must be scanned so the scanner will wait for an ACK or NAK from a bioptic scanner after each pack

Pagina 271

RussiaGost-R certificateSouth KoreaThis product meets Korean agency approval.TaiwanIf the following label is attached to your product, the product mee

Pagina 273

3 - 13Cordless System OperationNote: This chapter applies only to cordless scanning systems. It does not apply to corded scanners. How the Cordless C

Pagina 274

3 - 2Linking the Scanner to an Access PointTurn on the computer (laptop/desktop). Plug the interface cable into the Access Point first and then into

Pagina 275

3 - 3been properly sent to the base or Access Point, the scanner issues an error indication. You must then check to see if the scanned data was recei

Pagina 276

3 - 4Scanner Is Out of RangeThe cordless scanner is in communication with its base or Access Point, even when it is not transmitting bar code data. W

Pagina 277

3 - 5Charging InformationThe battery is designed to charge while the scanner is positioned in the cordless base unit. Refer to Base/Access Point LED

Pagina 278

3 - 6Caution: Danger of explosion if batteries are incorrectly replaced. Dispose of used batteries according to the recycle program for batteries as

Pagina 279 - Product Specifications

3 - 7Scanner LED Sequences and MeaningBase/Access Point LED Sequences and MeaningThe base contains a red LED and the Access Point has a blue LED that

Pagina 280 - Parameter Specification

3 - 8Base Power Communication IndicatorTo display the power indicator on a base or an Access Point, scan the Base Power Communication Indicator On bar

Pagina 281 - Specifications

3 - 9If you want to be able to scan bar codes while the scanner is in the base cradle, scan the Scanning in Cradle On bar code below. If you want to

Pagina 282

Caution: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.Pate

Pagina 283 - Depth of Field Charts

3 - 10Paging PitchWhen you press the Page button on the base or Access Point, the scan-ners associated with that base or Access Point will begin beep

Pagina 284

3 - 11The number of beeps and LED flashes emitted by the base for an error condition can be programmed from 1 - 9. For example, if you program this o

Pagina 285 - Standard Range

3 - 12Scanner ModesThe Xenon is capable of working in single scanner mode, multiple scanner mode, or with Bluetooth devices other than the CCB01-010BT

Pagina 286

3 - 13Locked Link Mode - Single ScannerIf you link a scanner to a base or an Access Point using the Locked Link Mode, other scanners are blocked from

Pagina 287 - 10 Pin RJ41 Modular Plug

3 - 14Override Locked ScannerIf you need to replace a broken or lost scanner that is linked to a base or an Access Point, scan the Override Locked Sca

Pagina 288

3 - 15The sounds are as follows:Scanner Power Time-Out TimerNote: Scanner Power Time-out Timer only applies to cordless systems. It does not apply to

Pagina 289 - Standard Cable Pinouts

3 - 16If there are no trigger pulls during the timer interval, the scanner goes into power down mode. Whenever the trigger is enabled, the timer is r

Pagina 290 - 10 Pin Modular Plug

3 - 17Flexible Power ManagementIf you are experiencing network performance issues, and suspect the scanner is interfering with other devices, you can

Pagina 291 - Maintenance

3 - 18Reset Scanner and Base/Access PointOnce the power level is set, you must scan the Reset Base bar code and wait for the scanner to unlink and rel

Pagina 292

3 - 19Default = Batch Mode Off.Batch Mode BeepWhen scanning in Inventory Batch Mode (page 3-19), the scanner beeps every time a bar code is scanned.

Pagina 293 - Replacing an Interface Cable

Product Agency Compliance - Xenon 1902 and CCB01-010BT BaseUSAFCC Part 15 Subpart CThis device complies with part 15 of the FCC Rules. Operation is s

Pagina 294 - Xenon Scanner

3 - 20RAM Storage: The scanner will not power down while it contains data that has not been transmitted to the base or Access Point, even if it reache

Pagina 295 - Troubleshooting a Base

3 - 21Example: Add a quantity of 5 for the last item scanned.1. Scan the item's bar code.2. Scan the quantity 5 bar code.Example: Add a quantity

Pagina 296

3 - 22Quantity Codes1032465789

Pagina 297 - Customer Support

3 - 23Batch Mode Output OrderWhen batch data is transmitted, select whether you want that data sent as FIFO (first-in first-out), or LIFO (last-in fir

Pagina 298 - Product Service and Repair

3 - 24Transmit Records to HostIf you are operating in Inventory Batch Mode (see Inventory Batch Mode on page 3-19), you must scan the following bar co

Pagina 299 - Limited Warranty

3 - 25To put the scanner in multiple scanner mode, scan the bar code below. Once you scan this bar code, the scanner is unlinked from the base or Acc

Pagina 300

3 - 26To rename scanners with sequential, numeric names, scan the bar codes below. Scan the Reset code after each name change and wait for the scanne

Pagina 301 - Reference Charts

3 - 27Application Work GroupsYour cordless system can have up to 7 scanners linked to one base or Access Point. You can also have up to 7 work groups

Pagina 302

3 - 28Application Work Group SelectionThis programming selection allows you to assign a scanner to a work group by scanning the bar code below. You m

Pagina 303

3 - 29To see what the factory default settings are, refer to the table of Menu Commands, beginning on page 11-5. The standard product default setting

Pagina 304 - Printable Characters

C-UL StatementC-UL listed: CSA C22.2 No.60950-1-07, 2nd Edition for I.T.E product safety.EuropeThe CE marking on the product indicates that this devic

Pagina 305 - Extended ASCII Characters

3 - 301. Scan the Bluetooth HID Keyboard Connect bar code below. 2. Set the Bluetooth-capable host device so it searches for other Bluetooth devices.

Pagina 306

3 - 311023675489Save

Pagina 307

3 - 32Bluetooth HID Keyboard DisconnectIf your scanner has been connected directly to an iPad, smart phone, or laptop using Bluetooth HID Keyboard Con

Pagina 308 - 104 Key U.S. Style Keyboard

3 - 33Changing the Scanner’s Bluetooth PIN Code Some devices require a PIN code as part of the Bluetooth security features. Your scanner’s default PI

Pagina 309 - Sample Symbols

3 - 34The table below shows the results of the Auto Reconnect On and Off set-tings: Maximum Link AttemptsThe Maximum Link Attempts setting controls th

Pagina 310 - Tes t Symbol

3 - 35of attempts to connect is limited by this setting. After the maximum number of attempts is reached, the scanner will not attempt to reconnect t

Pagina 311 - Test Message

3 - 36When the scanner goes out of range, 15 attempts are made to link to the base unit or Access Point. Each attempt consists of approximately 5 sec

Pagina 312 - Programming Chart

3 - 37• Host ACK must be set to On (page 3-38). • The host terminal software must be capable of interpreting the bar code data, make decisions based o

Pagina 313

3 - 38Host ACK On/OffHost ACK ResponsesCommand Action<ESC> a Double beeps to indicate a successful menu change was made.<ESC> b Razz or er

Pagina 314 - Xenon-UG Rev D

4 - 14Input/Output SettingsPower Up BeeperThe scanner can be programmed to beep when it’s powered up. If you are using a cordless system, the base ca